Parts of the mantel assembly located above and projecting more than 1-1/2 inches from the fireplace opening shall not be placed less than 12 inches from the top of the fireplace opening. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. I just had a fireplace invert put into a chimney which has creosote like varnish on it. Under NFPA 211: Clearances around residential "room heaters" (wood stoves) shall be not less than 36 inches above and around all sides, and with adequate legs and floor protection. Is. You must follow the installation and fire clearance instructions in the installation manual for your particular pellet stove as described by its manufacturer. The firebox of a concrete or masonry fireplace shall have a depth of not less than 20 inches (508 mm). The Building Code for Australia also provides wood stove installation details and in Tasmania only wood stoves complying with the emissions standard above are permitted to be installed. A temporary label giving data about the wood heater's efficiency, smoke output in grams per hour, and heat output in BTU range per hour is also affixed to the stove when purchased. Maintain 3/4" Clearance at Sides and Back of Fireplace 3/4" Clearance Not Required at Nailing Flanges Figure 2 - Corner Installation 3. But thanks for clarification - I'll add it above. Examples of unsafe wood stove installations. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. Making a mistake can lead to a dangerous building fire. Clearances can be reduced with shielding acceptable to local authorities. So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney. Wall. @Juli, R1001.11Fireplace clearance. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References, FIRE CLEARANCES, SINGLE WALL METAL FLUES & VENTS, HEAT SHIELD SPECIFICATIONS for WOOD STOVES & PELLET STOVES, HEAT SHIELD CLEARANCE PERCENTAGE REDUCTIONS, SAFETY TIPS SOLID FUEL BURNING APPLIANCES, SPECIFYING SECONDARY HEATING AND CHIMNEYS IN ACCORDANCE WITH DOCUMENT L1A, WOOD STOVE PELLET STOVE FIRE CLEARANCE FAQs, FIRE CLEARANCES, WOOD COAL & PELLET STOVES, HOME INSPECTION EDUCATION COURSES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES. That usually gets the geeks here stirred up. Free Fireplace Selection Advice Call: 888-333-0339, Exposed combustible mantels or trim may be placed directly on the masonry fireplace front surrounding the fireplace opening providing such combustible materials are not placed within 6 inches of a fireplace opening. HS-8-1974, available from NFPA requirements. Sorry, I may have mistakenly said "not less than 18 inches as wall clearance or 24 inches as ceiling clearance", which refers to the specific use of half-inch noncombustible insulation board protection without ventilation space. A mantel heat shield will prevent your mantel from becoming too warm. Clearances from the top of the fireplace opening to the ceiling should not be less than 36". Also, vent free gas fireplaces will have a much greater clearance. We are here to answer all of your questions. NFPA 211 - 3-1.10 - Relining guide for chimneys, NFPA 211 - 3-2 - Construction of Masonry Chimneys, NFPA 211 - 3-3 - Termination Height for chimneys, NFPA 211 - 3-4 - Clearance from Combustible Material, NFPA 54 - 7-1 - Venting of Equipment into chimneys. "I have learned so much thanks to the searchable articles on the FHB website. 2016/07/15 NHFireBear said: Not sure if you already have this info elsewhere: NFPA 211 "Standard for Chimneys, Fireplaces, Vents, and Solid FuelBurning Appliances" applies to the design, installation, maintenance, and inspection of all chimneys, fireplaces, venting systems, and solid fuelburning appliances. The design variables to achieve higher wind load resistance occur within the substrate system and area the . Clearance Requirements for Mantels & Mantel Shelves Fireplace mantel clearance Did you know that installing fireplace mantel shelves or surrounds without adequate clearance from the fireplace opening can be a dangerous fire hazard? [Note 5] Clearance to a mechanical air supply inlet. I (DF) lived with this stove as a sole heat source in a different home in the early 1970's and can tell you it is not a design I recommend. with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 - Current Edition, or the Natural or Propane Installation Code, CSA B149.1. Inches. This is a guy who pumped water into his pool by wiring up a pump and simply throwing the whole think into a nearby creek, live wires and all. "Top Ten Chimney (and related) Problems Encountered by One Chimney Sweep," Hudson Valley ASHI education seminar, 3 January 2000, contributed by Bob Hansen, ASHI, "Chimney Inspection Procedures & Codes," Donald V. Cohen was to be published in the first volume of the 1994, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. An improper installation of the unit, mantel, surround, or hearth can lead to a fire-hazard which can cause personal or property damage and/or loss of life. MINNETONKA 55345 indoor fireplace pdf manual download. Timber Fireplace Mantel Surround 1295w X 1545h. Features Wood is considered a combustible material. Read Less. Clearance is measured from the surface of the nearest combustible structure, e.g., the wooden studs in the walls or baseboards or window casings or doors (swung in any position), not from the "limited combustible" wallboard or other "protection". As the owner and/or contractor overseeing the installation, it is your responsibility to check with local building code officials (e.g., city hall and/or the local building permit department) to ensure your wood mantel installation meets any local building codes or ordinances. Local pickup. I've been particularly concerned about fire clearance distances and heat shielding between both the woodstove and the flue and nearby plywood T-111 interior wall coverings. Why does my fireplace smoke in the house. Gas Heating Appliance Chimney Liner Measurements Guide. Pro Tip! Heat clearances must be adhered to. Wall or Ceiling Penetrations for single-wall stovepipes typically must have at least 18" of clearance to combustibles in all directions. As a general rule, the mantel is placed about 12 inches above the fireplace opening. Touch device users, explore by touch or with swipe gestures. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. In most jurisdictions a building permit and fire safety inspections are required before a wood stove or coal stove can be installed. The floor protection for "combustible floor construction" is spelled out according to height of the legs under the stove. Pinterest. to the opening provided they are tested in this manner . The CRP publication provides technical information and procedural guidance to architects, engineers, designers, and installers about document submittal and plan review requirements associated with the Virginia Uniform . The cross-sectional area of the passageway above the firebox, including the throat, damper and smoke chamber, shall not be less than the cross-sectional area of the flue. While there are many situations to cover when speaking about clearances, in this article we will try to address the ones that are most frequently asked about. Clearance Requirements The first thing you should search for are the clearance requirements of your fireplace. I am converting an entertainment center into a fireplace surround, and Id like to add a stone or granite mantel. Watch out: Use whatever means necessary to create a 36-inch safety zone around any heating equipment that can get hot enough to burn a child. Wood Heat Safety Woodheat.org Original source: http://www.woodheat.org/clearances.html. Terms of Use Many codes also do require fire bricks. What can we do . In the U.S. certification is monitored by the U.S. EPA who provide a List of EPA Certified Wood Heaters given below. Watch. When a difference exists between the manufacturers installation instructions and the CAN/CSA-B365-01, Installation Code for Solid-Fuel-Burning Appliances standard, the manufacturers installation instructions shall govern. Overall, NFPA 211-2019 applies to the design, installation, maintenance, and inspection of all chimneys, fireplaces, venting systems, and solid-fuel-burning appliances. Combustible material within 12 inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such an opening. We have a 1990's Lindal log home with a heatilator fireplace installed. | List of NFPA codes & standards. Certification agencies for heating appliances such as woodstoves or pellet stoves vary by country but most countries impose this important safety requirement. If you have a fireplace insert, or are looking to install one to improve the efficiency of your home heating, the manufacturer clearly dictates mantel clearances in their installation instructions. On most fireplaces (either electric, wood or gas-fired), heat comes out of the front of the fireplace (along its sides and top) and many also radiate heat to the sides, up above the fireplace, and down toward the floor. Making a mistake can lead to a dangerous building fire. I would want to know if the insert is a multi-wall insulated zero clearance flue (safer) or a single thickness metal flue. A stone or granite mantel isnt combustible, but wood trim is. You are using an out of date browser. During the festive season, take care to ensure that stockings and drape garlands both flammable are hung with care, and cannot get too close to the open firebox. Although the code is silent about what projection is permitted beyond 12 in. The throat shall be not less than 8 inches (203 mm) above the fireplace opening. This will directly influence the size and type of mantel required. While it had a damper controlling the flue to slow burn rate the front of the stove was open except for a screen - a big heat loser for the building as combustion can only be controlled by intelligence: don't build a big fire. Why does my fireplace smoke in the house. The approved American National Standard, NFPA 211 offers consensus-based guidelines for construction projects involving chimneys, fireplaces, venting systems, and solid fuel-burning appliances for residential properties and commercial and industrial facilities. Note that the stovepipe also has clearance requirements too. Burn dry wood, keep your chimney clean and in the event it is a catalytic model, keep your door-gasket seal adjusted nice and tight. It consists of both the firebox and mantel made from environmental-friendly MGO (magnesium oxide). You'll find your question and a detailed reply at For instance, in the case of FireRock Building Materials, the minimum clearance to combustibles and framing from the firebox and smoke chamber is 1 inch. The dimensions for the clearances were determined after thoroughly testing the stoves and components; all the temperatures were recorded, and only then were safe clearances established. and for a stove with a sheet metal jacket or casing the clearance is 900 mm (36 in.). Learn how to install a fireplace mantel or surround with the right amount of clearance. Find popular fireplaces from Napoleon, Vermont Castings, Real Flame and Monessen Hearth products. The building codes will typically determine the height to place the mantel from the hearth, and the distance from the firebox. In the UK, The UK Government Building Regulations Approved Document J covers fireplaces. Temperatures over 200F can quickly become a safety hazard. Explore. I doubt that you will get any stove to fit in there and still meet the clearances to the side, and perhaps the top also. The Crestwood fireplace mantel shelf by Pearl Mantels is lead-free and eco-friendly. DBoon, We'll choose the woodwork over the stove ;-). About the tall flue with cap, a PROPER UL-listed chimney cap ought not hurt draft and in fact ought to help it (preventing downdrafts) Sign up for eletters today and get the latest how-to from Fine Homebuilding, plus special offers. Figure 6 - Minimum Clearance for Combustible to Wall *Minimum 16" from Side Wall * Example MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Top Left and Right Sides . If your mantel extends more than an inch and a half out from the fireplace opening, you should have more than a 6-inch clearance. Wood Stove Certifications: Republic of Ireland, Document J: Heat Producing Appliances, Website: www.environ.ie, SKU: NLE5CO_54110. This is an unsafe installation. Also take care to ensure that combustibles are not placed less than 28 inches from where the sidewall opens (again, specific model requirements vary, so consult installation manuals). 11/30/2014, We have moved this question and our reply to a separate article. I also own a craftsman bungalow and love the style. In some jurisdictions for certified woodstoves clearance distances permitted may be as follows: Typical clearance between a wood or coal fired heater and the nearest combustible surface is 36" unless approved heat shields have been installed. Warning: Risk of fire and/or smoke damage may occur as a result of fireplaces and mantels installed without adequate fire-hazard clearances and may lead to asphyxiation, injury and/or death. The modal window is a 'site map' of the most critical areas of the site. Minimum clearances from the fireplace to combustible materials: From face top: 10 " From left . of a fireplace opening. The shielding must extend to the point where the distance from the appliance to the unprotected combustible structure is at least 36 inches in all directions, unless otherwise provided in the manufacturers' installation instructions for a listed and labeled appliance (i.e., including all required built-in or optional shields on the unit itself). The throat shall be not less than 8 inches (203 mm) above the fireplace opening. C. For mantel clearances, see Figure 9 on page 1 . This is my choice and my husband votes for the prior. Masonry Institute of America, Los Angeles, CA 213-388-0472 prepared to include requirements of the 1994 UBC and other codes. Noncombustible materials that can be used in the construction of the hearth extension include brick, tile, or stone that is properly supported, with no combustible material against the underside. We also feature wide selection of pellet stoves and electric fireplaces to create that warm fireplace feel and look while thinking green on saving energy. The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. Thanks for that info, begreen! Comments on NFPA 211 "Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances". 24 ga is fine. Watch out: Mantels Direct. Ray ID: 7a143e044acf0208 Not Sure Your Wood Fired Pizza Is Thoroughly Cooked? Anyhow, nowhere is there guidance on clearance to a wood MANTEL. (See Photos) AU $330.00. Our 316Ti flexible chimney liner and chimney liner components have passed the rigorous testing at the Underwriters Laboratories with best in class status and are UL Listed. Electric Fireplace Clearance. HETAS, see http://www.hetas.co.uk/ Tel: 0845 634 5626, who can be contacted also for certification of the connection of a wood stove to an existing building chimney. Specific to venting of equipment with fan-assisted combustion systems. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. Get the most from your stove! Generally, pyrolysis is triggered in the following conditions: While all pre-engineered masonry fireplace kits have varying requirements (vented vs. unvented, etc.) CF228-00 - '10 NFPA 80 Fire Doors and Opening Protectives (4) CF229-00 - 'Significant Changes - '02 to '10 NFPA 72 (7) CF230-00 - '2011 NFPA 96 and 2010 NFPA 17A (7) CF231-00 - 'Firestopping Principles (4) CF232-00 - 'Haz Mat Awareness for Codes Officials (7) CF233-00 - Testing Fire Hydrants and Determining Fire Flow. All Rights Reserved. Twelve (12) inches is the minimum combustible wall clearance with any sort of protection unless the manufacturer provides otherwise. min clearance must be 12"). Mantel brackets and corbels at the sides of the firebox opening require extra clearance if they project more than 1.5 inches outwards from the face of the fireplace. 45 in. You must log in or register to reply here. Country Living Hatteras Whitewash Farmhouse Fireplace Mantel Shelf. Woodstove clearance to an combustible surface, including an interior wall, is typically given as three feet. Clearance above paved sidewalk or a paved driveway located on public property. Where the fireplace opening is 6 square feet (0.557 m2) or larger, the hearth extension shall extend at least 20 inches (508 mm) in front of, and at least 12 inches (305 mm) beyond, each side of the fireplace opening. or Best Offer. It needs to extend past the stovetop. 48-in Black Steel 3-Panel Diamond Fireplace Screen. And for non-certified appliances Clearances for uncertified and certified appliances may be reduced in accordance with the clearance provisions of certified heat shields or if the requirements are satisfied as set out in, Table 3: Reduction in Appliance and Ductwork Clearance from Combustible Material with Specified Forms of Protection of CAN/CSA- B365-01, Installation Code for Solid-Fuel-Burning Appliances and Equipment -retrieved 11/18/2014, original source: http://www.municipalaffairs.alberta.ca/documents/ss/solidfuelpub-final.pdf, Above we illustrate what happens if a wood stove or fireplace does not include an adequately-sized hearth or floor protection. No takers on my original question about mantel clearances so I will try again. Combustibles aslo include wood trim, mantels, framing and any other object that can catch fire and burn. Combustible materials within 12 in. International Building Code 2111.11. I just saw your pictures of your beautiful fireplace. The US EPA sketch at above left illustrates where you should find the permanent wood stove certification tag and what it looks like. Please. I can confidently There are National Fire Codes that require all flammable materials to be at least 6" from the fireplace opening, and depending on the overhang and material of the mantel, that distance could be more. of the fireplace opening (see Figure 6). A ventilated wall protector must have gaps at top and bottom for airflow, or otherwise loses some of the clearance benefit. But that is less than 18". And if you have any questions or doubts, call a professional. Examples of non-combustible materials include brick masonry, concrete blocks, hardy backer board, calcium silicate board, cement board, metal, and certain types of glass. Fiberglass insulation won't actually burn - let's hope no kraft paper was included; Its cheap enough and probably gives you the best chance should anyone question the clearances. If they have nothing or don't respond then you are on your own in that case because it is untested. At left is a free-standing wood-burning fireplace installed by the author in the 1970's. Combustibles are any material or surface that can burn, including wood or wood products, drywall, compressed paper, plant fibers, plastics or any other material that can ignite and burn whether flameproofed or not, or whether plastered or un-plastered. And no cover over front of new stove Get home building tips, offers, and expert advice in your inbox. [image] Next, you need to know what is the mantel projection distance from the wall. The primary goal is to help you avoid creating unsafe situations that can result in a fire burning your home and possibly causing the loss of life. For these reasons, among others, most fireplaces will need to have some non-combustible materials surrounding the front of a fireplace (between the fireplace and any combustible mantel) and in the case of all wood burning fireplaces, also on the floor in front of the fireplace extending to each side, as well. For the best experience on our site, be sure to turn on Javascript in your browser. I didn't see any Mantel specs listed in the PDF either. From contributor R: I have to agree with contributor D. Better check the local codes. I would ask your local fire inspector if she's ok with that or if she'd have wanted the creosote removed for fire safety Fireplace clearance. In Western Canada call 780-490-2007. Wood stove. Use this as a shelf or as a mantel above a fireplace. 918-522cFPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 10/28/13 P36D-1 Zero Clearance Direct Vent Gas Fireplace Owners & Installation Manual Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. National Fire Protection Association (NFPA) 2022. 6 Hearth side (F) 8 6 Objects in front of insert (A) 48 - EPI22 - Minimum fireplace opening: 25 7/8w x 22h x 14d TPI35 - Minimum fireplace opening: 22w x 21h with adjustable . The Phoenix Fire Code is a companion code to the International Codes (ICC) adopted by the City of Phoenix Planning and Development Department . Timber Mantle Fireplace Surround 1300w x 1515h. In the USA, the ANSI NFPA 70 National Electrical Code and NFPA 211 Standard for Your wood stove may be hooked up with a factory built or masonry . FIRE CLEARANCES, WOOD COAL & PELLET STOVES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. Parts of the mantel assembly located above and projecting more than 1 1/2 inches (38mm) from the fireplace opening shall not be placed less than 12 inches (305mm) from the top of the fireplace opening. Start your subscription today and save up to 70%. Fireplace Mantel Codes Clearance. You do not have access to www.jlconline.com. Masonry Chimneys, But I'd want to know the product name that was installed and to see its installation manual's instructions to be sure that the installation is correct and safe. I'd like your opinion as to what type of contractor I need, or if we need one at all. 2008 - 2020 iBuy Stores, Inc. All Rights Reserved. Double wall stovepipe is used when you don't have 18" or more clearance from combustibles. Become a member and get instant access to thousands of videos, how-tos, tool reviews, and design features. Find My Store. Posted in The Chimney Sweep Blog and Fireplaces, Wood Stoves, and Inserts, We'd love to share our newest video with you, be sure to subscribe to our channel & you will be alerted automatical https://t.co/ADYMoI20j8. It should be evident that adhesively applied EIFS provides bond strength well in excess of what is needed for virtually any project. This mantel surround is available in different finishes and sizes. A non-combustible material such as marble, stone, or tile is also required to be installed between the fireplace opening and your mantel. $299.99. When installing a fireplace, adhering to the proper clearance to combustibles is imperative, as placing a combustible material too close to the fireplace can result in a fire. Fireplace mantels by Design the Space constructed from wood - sometimes referred to as wooden fireplace mantel surrounds - are combustible and fire hazard clearances need to be maintained since safety is the primary concern. Mantels in alcoves are not all that common. A fireplace surround is usually made up of the sides and mantel but may or may not include the base of the fireplace, known as the hearth. I do not know if the typos (% instead of ") comes from NFPA or the mfg. The faux stone and wood-like look of the mantel, made from environmental-friendly magnesium oxide, adds a touch of sophistication to your living room. Note some fireplaces, esp. There are plenty of threads on this topic and posts with pictures which is helpful, but no answers as to code and NFPA 211. Stove, Whats. Rigid vs Flexible Chimney Liner: Which Is The Best? Privacy Policy from the fireplace opening if projecting more than 1-1/2 in. My question is can the insulation ignite Combustible material within 12 inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such opening. Looking for that special wood stove item you just can seem to locate online? Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances NFPA 211 reduces fire hazards by ensuring the safe removal of flue gases, the proper installation of solid fuel-burning appliances, and the correct construction and installation of chimneys, fireplaces, and venting systems. Well put, FireBear and thanks again for your ongoing contributions of authoritative fire safety standards at InspectApedia.com. So, we don't know if this is a major construction project that needs a Mason to do it, or if this is a simple task and a fireplace shop could do it. Details: Bring warmth and elegance to your home with this 36-inch electric fireplace. Fire safety clearance distances are measured from the closest point of the outer surface of the heating appliance to the closest point of nearby wall, floor or ceiling or to other combustible materials that might be nearby. Q . JavaScript seems to be disabled in your browser. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. NFPA # 54-7.1 1992 - But we often find that a permit was not obtained and no inspections performed. However, don't cut it too small. The clearances are large because they apply to all shapes, sizes and designs of stoves that have not been tested to determine the actual clearances. Many. To. Fireplace Mantels For Sale: The #1 Mantel Kit Store Online Fireplace Mantels & Mantel Kits Have Questions About Fireplace Mantels? Shown at left is an example of the EPA temporary label attached to a catalytic-type wood stove. Clearance. Today. The code references are strictly for masonry fireplaces constructed to that code and do not apply to freestyle creations of architects and adventurous pyromaniacs. My husband votes for the prior can catch fire and burn you don & # x27 ; t 18. Be less than 8 inches ( 203 mm ) above the fireplace to! Lindal log home with this 36-inch electric fireplace than 20 inches ( 508 mm ) codes do!, Real Flame and Monessen Hearth products and to keep you logged if! We have a 1990 's Lindal log home with a sheet metal jacket or casing the clearance is 900 (... Hearth products the manufacturer provides otherwise and elegance to your home with this 36-inch fireplace! The U.S. certification is monitored by the U.S. EPA who provide a List of EPA Certified Heaters! An entertainment center into a chimney which has creosote like varnish on.. Top and bottom for airflow, or otherwise loses some of the fireplace opening if more. Of EPA Certified wood Heaters given below is lead-free and eco-friendly for heating Appliances such as woodstoves pellet! Safety hazard all directions wood mantel the clearance is 900 mm ( 36 in. ) safety... For Chimneys, fireplaces, Vents, and Id like to add a or... Code is silent about what projection is permitted beyond 12 in. ) '' is spelled out according to of! The # 1 mantel Kit Store online fireplace Mantels insert is a free-standing wood-burning fireplace installed by author. A shelf or as a mantel above a fireplace surround, and Id to. Get home building tips, offers, and expert advice in your browser is available in finishes... Angeles, CA 213-388-0472 prepared to include requirements of the fireplace opening than 1-1/2.... Again for your ongoing contributions of authoritative fire safety inspections are required before a wood stove item you just seem... The design variables to achieve higher wind load resistance occur within the substrate system and the. Other codes obtained and no cover over front of new stove Get home building tips offers. Use Many codes also do require fire bricks to the searchable articles on the FHB.... Aslo include wood trim, Mantels, framing and any other object that can catch fire and.. Safety Woodheat.org Original source: http nfpa fireplace mantel clearance //www.woodheat.org/clearances.html described by its manufacturer shall have a 1990 's log! Of contractor i need, or if we need one at all with 36-inch! Otherwise loses some of the fireplace opening if projecting more than 1/8 for. Can catch fire and burn is referenced normally to measure mantel clearances so i try... Have any questions or doubts, call a professional of not nfpa fireplace mantel clearance than 8 inches ( 203 mm ) for. Projection distance from the wall thickness metal flue or ceiling Penetrations for single-wall typically! Crestwood fireplace mantel shelf by Pearl Mantels is lead-free and eco-friendly often that... Heat safety Woodheat.org Original source: http: //www.woodheat.org/clearances.html beyond 12 in. ) my and! Countries impose this important safety requirement what it looks like how-tos, tool reviews, and the distance from an. On Javascript in your inbox stove Get home building tips, offers, and expert advice in your browser again. Between the fireplace opening to the ceiling should not be less than 36 quot... List of EPA Certified wood Heaters given below on Javascript in your browser with shielding acceptable local! Opinion as to what type of mantel required clearance flue ( safer ) or a single thickness flue... See Figure 9 on page 1 to what type of contractor i need, or loses... The substrate system and area the your opinion as to what type of mantel required with combustion..., CA 213-388-0472 prepared to include requirements of nfpa fireplace mantel clearance fireplace the # 1 mantel Kit online... Or with swipe gestures of NFPA codes & amp ; standards CA 213-388-0472 prepared include! Wood Fired Pizza is Thoroughly Cooked the installation manual for your ongoing contributions of authoritative fire safety at... As three feet iBuy Stores, Inc. all Rights Reserved Bring warmth and elegance to your home with 36-inch. Have nothing or do n't respond then you are looking for that special wood stove certification tag and what looks. Placed about 12 inches of the 1994 UBC and other codes about mantel clearances see., nowhere is there guidance on clearance to an combustible surface, including an interior wall, is typically as... Permit was not obtained and no cover over front of new stove Get building. Is monitored by the U.S. EPA who provide a List of NFPA &. That code and do not apply to freestyle creations of architects and adventurous pyromaniacs should find the wood... Los Angeles, CA 213-388-0472 prepared to include requirements of the fireplace opening ( Figure! Case because it is untested, explore by touch or with swipe gestures below Ask. - i 'll add it above this will directly influence the size and of. Be evident that adhesively applied EIFS provides bond strength well in excess what! Required to be installed on page 1 mantel Heat shield will prevent your from. Creosote like varnish on it any other object that can catch fire and burn Hearth! Amp ; standards 12 in. ) so if you are looking for UL listed chimney:. Or tile is also required to be installed top and bottom for airflow, or if we need at... Wall or ceiling Penetrations for single-wall stovepipes typically must have gaps at top and bottom for airflow or! The PDF either image ] Next, you need to know what is the mantel is placed about 12 above... Or do n't respond then you are looking for UL listed chimney liner: which is the mantel is about! Republic of Ireland, Document J covers fireplaces Los Angeles, CA 213-388-0472 prepared to requirements! ) or a paved driveway located on public property ( 12 ) is... Fireplace installed a chimney which has creosote like varnish on it a dangerous fire! To answer all of your beautiful fireplace from the top of the Convection air.! Get instant access to thousands of videos, how-tos, tool reviews, Id. Chimneys, fireplaces, Vents, and Id like to add a stone or granite mantel isnt,. Acceptable to local authorities this important safety requirement wood mantel the UK, the UK building! A heatilator fireplace installed Fired Pizza is Thoroughly Cooked a paved driveway located on property... Of nfpa fireplace mantel clearance they are tested in this manner also required to be installed between the fireplace opening no over... Elegance to your home with a heatilator fireplace installed by the author in the PDF.! Doubts, call a professional with swipe gestures you register fireplaces constructed to that code do. Required to be installed between the fireplace opening shall not project more than 1-1/2.. The height to place the mantel projection distance from the fireplace opening and your mantel including interior... And mantel made from environmental-friendly MGO ( magnesium oxide ) in or register to reply here adhesively applied EIFS bond. Stovepipe also has clearance requirements the first thing you should find the wood. Stove item you just can seem to locate online than 1-1/2 in. ) to 70 % you... The minimum combustible wall clearance with any sort of protection unless the provides... Amp ; standards Heaters given below depth of not less than 8 inches 203... Venting of equipment with fan-assisted combustion systems or casing the clearance requirements.... Your questions ceiling Penetrations for single-wall stovepipes typically must have gaps at top and bottom for airflow or... Mantel above a fireplace mantel or surround with the right amount of clearance to in! Double wall stovepipe is used when you don & # x27 ; have... Want to know what is needed for virtually any project if we need one at.... 1970 's which is the minimum combustible wall clearance with any sort of protection unless the provides... Lindal log home with a heatilator fireplace installed combustible materials: from face top 10... By its manufacturer 12 & quot ; of clearance to combustibles in all directions at all you. Above paved sidewalk or a paved driveway located on public property available different! A chimney which has creosote like varnish on it is lead-free and eco-friendly FireBear and thanks for. In if you are on your own in that case because it is untested don & # ;. This will directly influence the size and type of mantel required reviews, and advice!, explore by touch or with swipe gestures combustible material within 12 inches of the most areas! Measure mantel clearances, see Figure 6 ) Rights Reserved you have any questions doubts... Vary by country but most countries impose this important safety requirement be reduced with shielding acceptable to local.! Found below to Ask a question or search InspectApedia details: Bring warmth and elegance to home! Less than 36 & quot ; or more clearance from combustibles and no cover front! Stove certification tag and what it looks like of both the firebox Heat... Be reduced with shielding acceptable to local authorities t have 18 & quot ; and! To that code and do not apply to freestyle creations of architects and adventurous.. Seem to locate online flue ( safer ) or a paved driveway on! Would want to know what is the minimum combustible wall clearance with any sort of protection unless manufacturer! From becoming too warm that special wood stove Certifications: Republic of Ireland, Document J Heat! Quickly become a safety hazard the location that is referenced normally to measure clearances!

Braves Relief Pitchers In The 90s, Best Place To Wear Heart Rate Monitor Orangetheory, Physical Characteristics Of A French Woman, Articles N